Page 114 - The Indian Optician Digital Edition November-December 2021
P. 114
and posterior chamber toric IOL implantation
is an effective option to correct pre-existing
astigmatism in a cataract surgery. In the
subjective questionnaire, the patients show
ratings between 7 to 10 on a scale of 10 which
shows satisfaction for distance and near vision
after the implantation of toric intraocular lens.
The present study summarises that the
implantations of binocular toric IOL in astigmatic
patients were an effective option to correct
pre-existing astigmatism in cataract surgery
with the implantation of toric IOL. There was no
significant difference between pre and post-K-
observational study was performed on 216 reading. It must be noted that the postoperative
eyes of 108 patients treated between 2016 to visual acuity is better and there is no residual
2021 for cataracts with astigmatism (cylinder astigmatism because it was corrected by the
≤ -4.00 Diopters). The patients previously implantation of toric IOL. Overall, the patients
underwent bilateral cataract surgery with were satisfied with the visual performance
phaco and implantation of Toric Intraocular because of less amount of refractive power.
lens. Refractive predictability, change in mean The patients also graded high satisfaction
spherical equivalent refraction, postoperative visual rating in postoperative subjective visual
uncorrected visual acuity (UCVA), and subjective experience.
visual outcome were compared in the first
month after the surgery. Pre-operatively, the KEYWORDS
patients had visual acuity between 1mFC to Pre-Op: Pre-Operative, Post Op:
6/18. After implanting toric IOL, 166 patients Postoperative, IOL: Intraocular lens
have 6/6 visual acuity, 49 patients have 6/9
visual acuity, and one patient has 6/12 visual REFERENCES
acuity. The p-value was <0.0000001 which is 1. Requirement for and Optimisation of
<0.05, i.e. statistically significant when testing Premium Intraocular Lenses, Gurpreet Bhogal
with two different pre-operative astigmatisms 2012 Aston University.
of subjective test reading and postoperative
astigmatism of subjective test reading in 2. Analysis and Correction of Corneal
patients with astigmatism between 1D-4D. In Astigmatism in Modern Pseudophakia by
a subjective questionnaire, the patient shows Catriona Ann Hamer Health and Human
a rating between 7 to 10 on a scale of 10. This Sciences Doctoral Training Centre 2015.
shows satisfaction for distance and near vision
after the implantation of a toric intraocular lens. 3. Evaluation of Modern Intraocular Lenses
Overall, the patients were satisfied with the Phillip Buckhurst 2011, Aston University
visual performance due to a lesser amount of ACKNOWLEDGMENTS
refractive power.
The article has been written under the
DISCUSSION guidance of Keyur N Sharma (Assistant
Professor, Shree Bharatimaiya College of
The p-value was <0.0000001 which is <0.05, Optometry & Physiotherapy, Surat), Dr.
i.e. statistically significant when testing with Mahendrasinh D. Chauhan (Principal,
two different pre-operative spherical equivalent Shree Bharatimaiya College of Optometry
readings and postoperative spherical equivalent; & Physiotherapy, Surat), Dr. Chetna V. Patel
reading in patients with cataracts.
(Vice Principal, Shree Bharatimaiya College of
The results indicate that phacoemulsification Optometry & Physiotherapy, Surat).
| NOV-DEC 2021 | 110 CASE STUDY