Page 100 - The Indian Optician Digital Edition November-December 2021
P. 100

A NEW



          TRIFOCAL CORNEAL




           INLAY  FOR

            PRESBYOPIA













                                                             PDCI DESIGN. THE BLUE AREAS IN THE LEFT
                                                             FIGURE REPRESENT A BIOCOMPATIBLE
                                                             (TRANSPARENT), HYDROGEL-BASED,
                                                             MATERIAL OF REFRACTIVE INDEX OF 1.458
                                                             (SEE “METHODS” SECTION FOR DETAILS).
                                                             THE IMAGE ON THE RIGHT IS A SIMULATION
                                                             OF THE APPEARANCE OF THE PDCI (IN
                                                             STARK CONTRAST) ON A REAL EYE





                 new pioneering implant to correct
                 presbyopia has been designed by
          A esearchers from the Universitat
                 r
          Politècnica de València (UPV), the
          Universitat de València (one of Spain's
          leading academic institutions) and the
          Aiken Ophthalmology Clinic’s Research
          Foundation, following five years of research.
          The team’s work has been published in
          Nature group’s Scientific Reports journal.
             They have created the first trifocal
          corneal inlay that is also fully transparent.     AMTFS OF PDCI (MAGENTA) AND RCI (BLUE) FOR 3.0 MM
          The inlay would allow people with                 (A), AND 4.5 MM PUPIL (B). DOTTED LINES CORRESPOND
          presbyopia good vision of objects located at      TO THE AMTFS WITH THE OPTICAL INLAYS DECENTERED
                                                               1.0 MM WITH RESPECT TO THE PUPIL CENTER AS
          several distances, whether far, intermediate         SHOWN IN THE PHASE MAPS SHOWN WITH THE
          (as in computers and mobile devices) and         CORRESPONDING COLOR FRAMES IN (C) FOR 3.0 MM AND
                                                                     (D) FOR 4.5 MM PUPIL DIAMETERS
          near for reading.

             According to Juan Antonio Monsoriu,          THE NEW CORNEAL INLAY COULD PROVE
          researcher, Centre for Physical Technologies
          at the UPV, the inlay could be an alternative   TO BE AN ALTERNATIVE FOR THOSE WITH
          for those with presbyopia who would              PRESBYOPIA WHO WOULD RATHER NOT
          rather not use glasses or contact lenses.           USE GLASSES OR CONTACT LENSES
          “Furthermore, it would be fully compatible


           | NOV-DEC 2021 | 96  TECH UPDATE
   95   96   97   98   99   100   101   102   103   104   105