Page 38 - The Indian Optician Digital Edition Jan-Feb 2020
P. 38

ACUTE RETINOPATHY                    Only three patients showed fully   both, were detected in 67%.
          CAN LEAD TO VISION                reversible changes. Another three     The research team hopes these
                                            had prolonged and likely permanent
          LOSS IN PXE PATIENTS              vision loss due primarily to central   findings will contribute to the
                                                                               understanding of variable ocular
            A   research team based in      sub-retinal hyper reflective material   disease progress in PXE and provide
                Germany has found that acute  originating from angioid streaks.
                                                                               insights into the autoimmune
          retinopathy may, in some cases,   Anti-retinal or anti-RPE antibodies, or   phenomena of the posterior pole.
          explain vision loss and other disease
          manifestations in patients with   OPTICAL IMAGER TO IMPROVE DRY EYE
          pseudoxanthoma elasticum (PXE).   DIAGNOSIS AND TREATMENT

             The team appraised 167 patients       new non-invasive optical    Advanced Optical Methods Ltd.
          with PXE from May 2013 to October   A    imaging system that promises   in Israel. “Our Tear Film Imager is
          2018. The subjects were asked to go   to improve diagnosis and treatments   the first device that can be used in
          through various imaging exams such   for dry eye disease has been    the ophthalmology or optometry
          as fundus photography, fundus auto-  developed by Israel researchers.   setting to image the tear film and
          fluorescence (FAF), OCT, fluorescein   Dry eye usually occurs when there   distinguish its inner layers with
          angiography (FA), indocyanine green   is instability in the inner layer of the   nanometer resolution.”
          angiography (ICGA) and, in some   tear film that protects the outside of
          cases, electro-retinography and   the eye.                              The new instrument uses an
          anti-retinal pigment epithelium (RPE)                                eye-safe halogen light to illuminate
          antibody testing.                    The researchers, including      the eye, and then analyses the
                                            those from the Optical Society in   full spectrum of light reflection
             The study reported in JAMA     the US, said that most cases of dry   happening over time and space.
          Ophthalmology states that the     eye are diagnosed using patient    The measurements, completed
          researchers identified nine patients   questionnaires, which may be   automatically in just 40 seconds,
          with acute retinopathy, with      subjective and are not ideally used   are used to reconstruct the
          symptoms ranging from short-term,   to identify the cause of the disease.   structures found in the front of the
          reversible alterations to irreversible   Objective methods for examining   eye, allowing ophthalmologists to
          vision loss. Also, all nine had fundus   the tear film tend to be invasive   accurately measure the tear film
          alterations, including similarities   and cannot track rapid changing   inner layers, particularly the aqueous
          with multiple evanescent white    dynamics, which are altered with   sublayer which plays an important
          dot syndrome.                     every blink.                       role in dry eye.

             The various tests indicate that,   The study, published in the       The Imager measured the
          of the nine with retinopathy, 67%   Optical Society (OSA) journal Applied   tear film consistently including
          experienced visual acuity reductions.   Optics, describe the device’s ability   blinks every few seconds, and the
          All patients revealed characteristic   to perform spectral measurements   measurements correlated well with
          fundus features with temporary    across a large field of view in a matter   other partially invasive, commonly
          appearance of partly confluent outer   of seconds. The researchers report   used dry eye diagnostic techniques,
          retinal whitish dots at the posterior   that the imager can acquire fast   the study noted.
          pole, which corresponded with areas   and consistent measurements from   The research study was
          of hyper-autofluorescence on fundus   human eyes even when blinking.  performed at AdOM Advanced
          FAF, loss of the ellipsoid band on OCT   “Up to 60 percent of        Optical Methods laboratory.
          and associated scotomata. The FA   ophthalmology office visits are   The proof of concept, unique
          and late-phase ICGA imaging showed   due to dry eye, pointing to the   method and design that enable
          associated hyperfluorescence      need for a non-invasive and highly   measurement of ultra-thin tear layers
          and hypocyanescence.              accurate device for diagnosis in the   with nanometer resolution were
          Electroretinography revealed a    office setting,” said research team   developed by AdOM’s development
          variable reduction of amplitudes.  leader Dr. Yoel Arieli from AdOM   team led by Dr. Yoel Cohen.


           | JAN-FEB 2020 | 34  OPHTHALMIC NEWS